What We Do: We fabricate a custom set of panels to match any particular home set, within limitations, and can have those panels delivered to your jobsite. We provide relevant construction details and we are available for technical support regarding your panel installation, but please review the installation instructions download first. We are happy to mail it, along with a DVD, if you like. What We Don't Do: We do not provide any site evaluation to determine the suitability of this or any conventional foundation for a particular site. This evaluation needs to be made by the appropriately knowledgeable person to determine if this or any conventional foundation is suitable for the building site in question. |
Our foundation panels have been thoroughly tested and found to be entirely safe for carrying multi-story loads with backfill in any seismic zone. |
|
|
|
||
|
Jump to: |
||
|
|
MEDIA PRESENTATIONS | |
|
|
INFORMATIONAL BROCHURES | |
|
MEDIA PRESENTATIONS |
||||||||||||||||||||||||||||||
|
|
Video Clip on Manufactured Homes | |||||||||||||||||||||||||||||
|
|
Installing the Anchorpanel
Foundation onto a Manufactured Home A very brief presentation of bits of the panel installation process enough to get a basic idea. For much more visual information, please ask us to mail you our DVD. [MH-VidSS1.wmv | 3.0Mb] |
|||||||||||||||||||||||||||||
|
|
Narrated Video Slide Shows of Various Anchorpanel® Foundation Projects | |||||||||||||||||||||||||||||
|
|
Anchorpanel for Site-Built
Homes Various methods of applying the Anchorpanel perimeter to stick-built projects. [SB-SS_web1.wmv | 1.4 Mb]
|
|||||||||||||||||||||||||||||
|
|
Examples of Anchorpanel
Installations onto Manufactured Homes [MH-SS_web1.wmv | 1.4 Mb] |
|||||||||||||||||||||||||||||
|
|
Anchorpanel for Retrofit
Homes [RF-SS_web1.wmv | .8 Mb] |
|||||||||||||||||||||||||||||
|
|
Anchorpanel for Unique
Applications [UA-SS_web1.wmv | 1.5Mb] |
|||||||||||||||||||||||||||||
|
|
Anchorpanel Technical
Information Provides some basic installation and engineering information on the foundation system, primarily addressing its use with manufactured homes. This includes specifics on panel layout given particular footprints and site slopes. There are slides of technical drawings, which can be downloaded from this site, or hard copies mailed to you (along with more detailed info). [TI-SS_web1.wmv | 2.5Mb] |
|||||||||||||||||||||||||||||
INFORMATIONAL BROCHURESWe are happy to mail you higher resolution hard copies. Please contact us. |
|
|
|
Site-Built Homes |
|
|
Stick-Built Home Foundations |
|
|
Retrofit Foundations A 2-page brochure with introductory information on cost effectively utilizing the Anchorpanel system for retrofitting the perimeter foundation of older site-built homes on outdated post and pier supports. Homes receiving these retrofits meet Model Building codes and so typically can qualify for conventional mortgages. [Retrofit.pdf | 370Kb] |
|
|
Manufactured Homes (also relevant to Modular Home foundations.) |
|
|
Overview of the System as used with Manufactured Homes HTML version- (Click Here) Presents the Anchorpanel foundation in a technical yet simple format. This is presently our best overview of the system, and has informative benefit beyond use manufactured homes. [MH_TechOverview.pdf | 400Kb]
|
|
|
Shows various examples and the procedure for using the Anchorpanel foundation for the low-set (pit-set) of manufactured homes. The front side presents photos illustrating visual benefits of a low-set, and the back has some technical drawings and info on the panel installation. [MH_LowSet.pdf | 260Kb]
|
|
|
Manufactured Home Foundations Introduction Our first brochure on the use of Anchorpanel with manufactured homes. It highlights the benefits of using the Anchorpanel perimeter over conventional construction. [MH_Intro.pdf | 380Kb] |
|
|
Modular Homes |
|
|
Modular Home Sequence HTML version- (Click Here) This document illustrates an efficient sequence for installing a modular home with the Anchorpanel perimeter foundation, where a crane is not required for setting the home. [MOD_SEQ.pdf | 269Kb]
|
|
COMPLIANCE DOCUMENTS (which we'll gladly mail to you for better quality!) |
|
|
|
Code Compliance Documents for Manufactured Housing |
|
|
California MH Foundation Standard Plan Approval 11x17 full page Download Our State of California Standard Plan Approval for a permanent foundation for manufactured homes, expiring 08/02/09. This is the document you need to apply for a permit for a permanent-foundation installation of a manufactured home with the Anchorpanel foundation in all jurisdictions in California. Homes installed to this standard also satisfy the loading design criteria of both the CA Earthquake Resisting Bracing System and Tiedown System. This download is split into two halves of the 11 x 17 original. [MH_CA_SPA-07.pdf | 424Kb]
|
|
|
Idaho
State Approval Our Approval for the State of Idaho for a permanent foundation for manufactured homes, meeting FHA-Lender requirements. This approval allows installations where snow loads are up to 200 pounds per square foot. Our general state approval for all MH installations is in process. [MH_ID_SPA.pdf | 360Kb]
|
|
|
Texas Manufactured Home Foundation Design The design document for our Texas State approval of the Anchorpanel Foundation as a Stabilizing System for manufactured homes, expiring 06/06/15. This approval covers the entire state, with the exception that single-wide units are not included within 1500 feet of the Gulf coast. You need this document along with the Texas Certification (MH_TX_CERT.pdf) below to apply for a permit for an installation of a manufactured home with the Anchorpanel foundation. This download is split into two halves of the 11 x 17 original. [MH_TX_SPA-15.pdf | 320Kb]
|
|
|
Texas Manufactured Home Stabilizing System Certification This is the Texas Certification of the Anchorpanel foundation for permanent installations of manufactured homes according to Texas requirements. This document corresponds to our Texas foundation design document above. This state approval is valid until October 2015. [MH_TX_CERT.pdf | 320Kb]
|
|
Gulf States Certification -
These documents are for home installations in the Gulf States, provide a design that complies with the International Residential Code and International Building Code (IRC/IBC), and the HUD code for installations of manufactured homes in the states of Louisiana, Mississippi, and Alabama, for wind speeds up to 140 mph, exposure C. The documents are identical for all states, except the Engineer’s seal affixed is that for each respective state. [MH_LA_SPA.pdf | 370Kb], [MH_MI_SPA.pdf | 610Kb], [MH_AL_SPA.pdf | 365Kb]
|
|
|
|
FEMA-85 Multi-Hazard Mitigating Foundation Design The 4-page document for our compliance with the newly revised FEMA-85 Multi-Hazard-Mitigation foundation design for manufactured homes. The installation of the Anchorpanel perimeter is engineered to meet the criteria of FEMA-85, according to the most recent draft rewrite of that standard. Our compliance is for double-wide homes in type A non-coastal flood zones, for flooding up to 5 feet deep and at up to 5 feet per second velocity, and for winds up to 140 mph. Our system can safely support homes outside of these parameters, such as single-wide in deeper floods, etc, but specific engineering calculation and design is then required to address that installation. [MH_FEMA-85.pdf | 524Kb]
|
|
Arizona and Wyoming Manufactured Home Foundation Design For this State Approval please contact PermaRock Foundations in AZ: 800 714-3478 or 520 466-8310 |
|
|
|
Code Compliance
Documents for Modular Housing Note: Most building jurisdictions require site-specific engineering approval for modular home installations. |
|
|
This is our document for compliance with the Mississippi Emergency Management Agency design for state sponsored modular housing units built to replace homes destroyed by hurricane Katrina. This foundation design meets all MEMA requirements including the new 150 mph wind design requirement. [MH_MEMA.pdf | 310Kb] |
|
|
Code Compliance Documents for Commercial Modular Buildings |
|
|
California CM Foundation Standard Plan Approval |
|
|
Code Compliance Documents for Model Building Code Construction |
|
|
International Code Council Evaluation Report, Testing and
Calculation Results |
|
|
Lender / Underwriter Requirement Compliance Documents for Manufactured Housing |
|
|
FHA-HUD Compliance Foundation Design
|
|
|
FHA-HUD Compliance Foundation Memorandum This document, dated 2/28/05, is from the engineering department of FHA, where it has been determined that the Anchorpanel foundation system complies with the HUD standards described above, and therefore is eligible for FHA permanent mortgage financing. [HUD_Memo.pdf | 316Kb]
|
|
|
USDA Rural Housing Lender Compliance This document, dated 2/28/05, is from the engineering department of FHA, where it has been determined that the Anchorpanel foundation system complies with the HUD standards described above, and therefore is eligible for FHA permanent mortgage financing. [USDA_Rural.pdf | 65Kb] |
|
INSTALLATION DOCUMENTS (which we'll gladly mail to you for better quality!) |
|
![]() |
Technical Information for Installing the Anchorpanel Foundation onto Manufactured Homes. Please note that this information is also relevant to the installation of the Anchorpanel system for modular (model code), site-built, and panelized home construction. Information specific to these applications is forthcoming. |
|
|
Ordering the Anchorpanel Foundation for Manufactured Homes A one-page text document with information you need to order the Anchorpanel system for your foundation project. [Ordering_Anchorpanel_MH.pdf | 316Kb]
|
|
|
Ordering and Installing the Anchorpanel Foundation for Manufactured Homes A 10-page text document with diagrams and information on installing the Anchorpanel system. This document is not to be considered training material for those who are not already familiar with construction practices. [Installing_Anchorpanel_MH.pdf | 232Kb]
|
|
|
Installation Diagrams for Manufactured Housing Foundations This file is 4 pages of the same diagrams that are on the Installation text (above). These are better quality diagrams than those on that text document. [Installation_Diagrams.pdf | 275Kb]
|